| Blackbox mode || Range: between 0 and 255 || <div style='text-align: center;'>X</div> ||
| Blackbox mode || Range: between 0 and 255 || <div style='text-align: center;'>X</div> ||
|-
|}


==== Blackbox admin settings - control register ====
==== Blackbox admin settings - control register ====

Revision as of 09:53, 15 August 2023

Only available in: BSS and BMS


Open configurations overview screen

The configurations screen can be opened for one or more ships, in the following ways from the the ship overview:

  • under menu-item InfoConfigurations;
  • by right clicking the mouse and choose Configurations from the pop up menu.

After the desired period selection has been entered, the screen will be opened.

Configurations overview screen content

Column Content
Ship The ship code
From The date time from which the configuration is active
Until The date time until the configuration is active. If it's the current configuration, the date time will be '2999-12-31 00:00:00'
Configuration date The datetime of the last configration update, noted as dd-mm-yyyy hh-mm-ss
Software date The datetime of the last software update, noted as dd-mm-yyyy hh-mm-ss
Software version The current software version on the blackbox
Serial number The serial number of the blackbox

Edit and send a configuration

The configuration screen is divided in two tabs: 'General' and 'settings'.

Open configuration screen

The screen in which a configuration can be edited and send, can be opened from the configuration screen by double clicking on a line.

Configuration: General

In the General tab the parameters are divided in 6 blocks.

Depending on the user, the following parameters are shown:

Blackbox information

Some of the parameters are readonly.

Parameter Meaning User Dependent Readonly
Ship The ship code
X
Serial number The serial number of the blackbox
X
BB Config ID
X
Blackbox name The blackbox name
X
Software date The datetime of the last software update, noted as dd-mm-yyyy hh-mm-ss
X
Software ID The software ID
X
Software name The software name
X
Software version The current software version on the blackbox
X
Configuration date he datetime of the last configration update, noted as dd-mm-yyyy hh-mm-ss
X
Default configuration
X
Ship ID The ship ID
Range: 0 - 255

Connection settings

Parameter Meaning User Dependent Readonly
Maximum connection attempt Range: between 0 and 10
Timeout communication attempt (sec) Range: between 6 and 100 seconds
0: Main server
X
1: Main port
X
2: APN
X
3: User name
X
4: User pwd
X
5: Backup server
X
6: Backup port
X
Nr. 1 - 4
Service number
Analogue number
Collecting data number

Interval settings

Parameter Meaning User Dependent Readonly
Interval standby (sec) Range: between 120 and 43200 seconds
Interval unknown (sec) Range: between 1 and 43200 seconds
Namur check time (sec) Range: between 0 and 65535 seconds
X

Alarm settings

Parameter Meaning User Dependent Readonly
Power alarm delay (sec) Range: between 0 and 100 seconds
Gps alarm delay (sec) Range: between 120 and 3600 seconds
*Sms collect time (sec) Range: between 0 and 255
*Sms start time (sec) Range: between 0 and 23
*Sms end time (sec) Range: between 0 and 23
Max sms messages per day Range: between 0 and 60
Sms service number
Sms number
Intervention code Range: between 0 and 999
*Sms collect time is in minutes, sms start and end time is in hours. The texts will be adjusted in v2.18.

Blackbox admin settings

Parameter Meaning User Dependent Readonly
Battery monitor shunt (mOhm) Range: between 0 and 65535
X
Battery nominal capacity (mAh) Range: between 0 and 65535
X
Blackbox mode Range: between 0 and 255
X

Blackbox admin settings - control register

Parameter Meaning User Dependent Readonly
Bit 08 Serial TxA enabled
X
Bit 09 Serial RxA enabled
X
Bit 10 Serial TxB enabled
X
Bit 11 Serial RxB enabled
X
Bit 12 Serial TxC enabled
X
Bit 13 Serial RxC enabled
X
Bit 14 NMEAIN 1 enabled
X
Bit 15 NMEAIN 2 enabled
X
Bit 16 Accept available
X
Bit 17 Buzzer available
X
Bit 18 Terminal available
X
Bit 19 Spare
X
Bit 20 Spare
X
Bit 21 Spare
X
Bit 22 Spare
X
Bit 23 Spare
X
Bit 24 Spare
X
Bit 25 Spare
X
Bit 26 Spare
X
Bit 27 Spare
X
Bit 28 Spare
X
Bit 29 Log extra data
X
Bit 30 Log extra data modem 0
X
Bit 31 Log extra data modem 1
X

Terminal settings

Configuration: Settings

Retrieve last blackbox configuration

Retrieving the last blackbox configuration manually is currently possible for one ship at a time. To retrieve the configuration for a specific ship, right click on the ship in the ship overview screen and click Retrieve last blackbox configuration. The following screen opens, in which the statusses of the processes are shown:

If a connection can be made with the blackbox, the current binairy configuration will be retrieved directly from the blackbox.

After the configuration is retrieved, you can click OK to close the window and return to the ship overview. If you want to cancel the process in the meantime, click on Cancel. The configuration will not be retrieved then.

Note: if you would like to see the communication from and to the blackbox during the retrieval of the configuration, you first have to open the Terminal screen.