Monitor blackbox: Difference between revisions

From Blackbox stations
Jump to navigation Jump to search
Line 199: Line 199:
| Power alarm delay || The delay setting when the board voltage alarm is acitve.||
| Power alarm delay || The delay setting when the board voltage alarm is acitve.||
|-
|-
| Interval unknown || Registration if the ship status cannot be determined, noted in seconds.||
| Interval unknown || Registration if the ship state cannot be determined, noted in seconds.||
|-
|-
| Interval standby || Registration interval on internal battery (without on-board voltage), noted in seconds.||
| Interval standby || Registration interval on internal battery (without on-board voltage), noted in seconds.||

Revision as of 07:22, 21 February 2023

Only available in: BSS and BMS

Monitoring a black box shows the current state of the black box.

Monitor a blackbox

A blackbox can be monitored one ship at a time. To open the monitor screen, right click the mouse on the relevant ship in the ship overview screen and choose Monitor blackbox from the pop up menu. A connection with the blackbox is being attempted. If succesfull, the monitor screen will gradually fill with data.

Note: if you would like to see the communication from and to the blackbox during monitoring mode, you first have to open the Terminal screen.

Monitor screen content

The monitor screen is divided in 11 blocks, in which the following data is shown.

GPS data

The following information is displayed in the GPS data block:

Field Content
Date The date in the blackbox, noted as ddmmyyyy
Time The time in the blackbox, noted as hhmmss
Latitude Latitude of the position in [00]DDMM.MMMM N/S
Longitude Longitude of the position in [0]DDDMM.MMMM E/W
Speed The gps speed from 0.0 - 99.9
Course The course in degrees
GPS quality code The gps quality in code (0, 1, 2, 3)
D quality The gps mode in code (1, 2, 3) with suffix:
- -o for gps antanna open
- -s for gps antenna short
Average speed The average speed in knots

Analogue inputs

The following information is displayed in the analogue inputs block, per analogue input:

Column Content
Name The analogue input
Value The analogue input value in mV
LA The analogue input low alarm in mV
HA The analogue input high alarm in mV
Hys The hysteresis in mV
Filter The filter in seconds
Delay The alarm delay in seconds

Pulse inputs

The following information is displayed in the pulse inputs block, per pulse input:

Column Content
Name The pulse input
Value The pulse input value in mV
DC The ratio of the time that the pulse input is active and the total period, noted in percentage
PPR The number of pulses per revolution
Factor The configuration factor for gear or shaft of the pulse input

Ship state settings

Under construction 

System info

The following information is displayed in the system info block:

Field Content
Ship The ship code
Serial number The serial number of the black box
Version BB application The current software version on the blackbox, noted as P13140-10 {version number}
Version BB bootloader The current bootloader version on the blackbox, noted as P13140-20 {version number}
Blackbox type The type of the blackbox
Last configured The datetime of the last configuration, noted as dd-mm-yyyy hh-mm-ss
Last updated The datetime of the last software update, noted as dd-mm-yyyy hh-mm-ss

Alarms

Under construction

Board monitoring

The following information is displayed in the board monitoring info block:

Field Content
Board supply Voltage of the board supply, noted in mV
Supply charge Voltage of the charge supply, noted in mV
Supply battery Voltage of the battery supply, measured with controller, noted in mV
Supply bat mon Voltage of the battery supply, measured with battery monitor, noted in mV
Charge current Charge current of the battery supply, measured with controller, noted in mA
Charge current mon Charge current of the battery supply measured with battery monitor, noted in mA
Battery capacity Current capacity of the battery supply, noted in %
Battery temp Temperature of the battery, noted in °C
Supply namur 1 The pulse input supply, noted in mV
Supply namur 2 The pulse input supply, noted in mV
Supply 5V Voltage of the 5V supply, noted in mV
Supply 5V_W Voltage of the 5V_W supply, noted in mV
Supply 3V4 Voltage of the 3V4 supply, noted in mV
Board temp Temperature of the board supply, noted in °C
Supply 15V Voltage of the positive 15V switched supply, noted in mV
Supply -15V Voltage of the negative 15V switched supply, noted in mV

Jumpers

Under construction

Status info

The following information is displayed in status info block:

Field Content
Registration pointer The pointer of the last retrieved registration
Ship state State of the ship
Recording paused Feedback after the terminal was paused to read data
Record buffer full Logging buffer of the records is full
BB status State of the blackbox
Failure counter Number of blackbox failures

Modem info

The following information is displayed in the modem info block:

Field Content
GSM signal quality Quality of the gsm signal
GSM signal strength Strength of the gsm signal, noted in dB
GSM state State of the gsm signal
GSM substate Substate of the gsm signal
SMS number The mobile number used for text messages
SMS service number The mobile service number used for text messages
SMS collect time Length of time for collecting text messages, noted in minutes
SMS start time Start time of reading text messages, noted in hours
SMS end time End time of reading text messages, noted in hours
Max SMS messages per day The maximum number of sms messages send per day

Setting info

The following information is displayed in the setting info block:

Field Content Fleet dependent
GPS alarm delay The delay setting when the GPS alarm is active.
Power alarm delay The delay setting when the board voltage alarm is acitve.
Interval unknown Registration if the ship state cannot be determined, noted in seconds.
Interval standby Registration interval on internal battery (without on-board voltage), noted in seconds.
State deep disabled If the blackbox should beep during a transition:
- True: beeping is on
- False: beeping is off
Text message duration Message duration of a text message.
X
Max concessionaires Number of maximum concession holders that can be set.
X

Monitor data screen

To open the monitor data screen, click on the menu item Monitor data in the monitor screen.